Detailed introduction

Helium Leak Testing Services

If a leak is present, the gas analyzer in the unit alarms and the leak point may then be identified. With standard helium leak detection equipment a leak rate as low as 110-9 cc/second can be detected. A leak this size would take approximately 3.17 years to leak one cubic centimeter of helium through the leak. Get price

Helium Leak Testing

Clients may request helium leak testing to assess the performance of a material or to analyze or evaluate component longevity. Helium is the preferred leak testing medium because technicians can detect and measure it at minute leak rates (less than 1 cubic centimeter/300 years) and because the gas is inert, meaning it will not react with most components being tested. Get price

Helium

MD-490S Dual Gas is the most advanced sniffing Helium/Hydrogen leak detector designed specifically for industrial environments. The MD-490S Dual Gas utilizes VIC's own industrial-grade mass spectrometer to achieve the highest sensitivity, fastest response-time, and smallest footprint. With a touch of a button, this dual gas unit can detect either Helium or Hydrogen tracer gases, while using Get price

Helium Leak Detection

Helium Leak Detection Provac are specialists in on-site Helium leak detection . Even the lowest detectable leak rates can be located quickly and with the minimum of interruption, using the market-leader Leybold PhoeniXL300 Helium leak detector in both vacuum mode (evacuated systems) and sniff mode (pressurised vessels) for helium leak detection. Get price

Helium or Air? Leak Testing Realities, Economics and

Oct 11, 2013Helium mass spectrometry is among the most expensive leak testing methods used to find micro leaks in items such as air conditioning components and air bag systems. This method is insensitive to part variations such as expansion and temperature. However, vacuum pumps, nitrogen purges and stringent maintenance are expensive and time consuming. Get price

Maintenance procedures: leak detection in vacuum furnaces

Mar 16, 2017How to perform the leak test in a vacuum furnace. There are two conditions for performing the leak detection in a furnace:. The least sensitive is when the pressurized system is sealed and a sniffer is used on the outside in order to locate any leaks.Since helium is a very light gas (with respect to air) it tends to rise. Get price

Helium mass spectrometer

A helium mass spectrometer is an instrument commonly used to detect and locate small leaks. It was initially developed in the Manhattan Project during World War II to find extremely small leaks in the gas diffusion process of uranium enrichment plants. It typically uses a vacuum chamber in which a sealed container filled with helium is placed. Helium leaks out of the container, and the rate of Get price

Helium Leak Testing

Helium Leak Testing, Inc. Excels in Leak Detection Testing Services for Research, Industrial, Commercial, and Production Operations in all aspects of industry. A2LA Accredited Helium Leak Testing calibration laboratory is certified and accredited to calibrate all types and brands of vacuum gauges. Get price

Fundamentals of Leak Detection: The Complete Guide

Standard helium conditions are always present during helium leak detection for a vacuum system when the system is connected to a leak detector. If the system is pumped down too p less than 1 mbar and if it is sprayed with helium mass 4, one refers to the spray technique. Get price

Helium Leak Detection

Helium leak detection is among the most reliable and effective testing methods available for testing the structural integrity of welds. It is a crucial process that has helped make us a leading manufacturer of vacuum component parts. Using helium mass spectrometers, we perform vacuum leak detection tests on all our welded parts and components. Get price

Helium Leak Detection

Helium leak detection is among the most reliable and effective testing methods available for testing the structural integrity of welds. It is a crucial process that has helped make us a leading manufacturer of vacuum component parts. Using helium mass spectrometers, we perform vacuum leak detection tests on all our welded parts and components. Get price

Leak Testing Pressure Testing: Guide to helium leak test

What are the benefits of Helium Leak Testing? Using this technique you can leak test to find smaller leaks than with other test processes, using a largely temperature independant, dry technique. This should result in a longer product life. There are 2 basic techniques; high vacuum testing which allows leak test thresholds to be set down as low as 110-12 mbar.l.sec-1, or sniffing which is generally used for Get price

Guide to Good Leak Testing

A trace of hydrogen or helium with the nitrogen will enable leaks to be found at a lower pressure. A suitable electronic detector must be used – your standard detector is not sensitive to hydrogen or helium. Nitrogen can be supplied with a trace of hydrogen (as shown in the photo) or helium specifically for leak testing. Use a reference leak to Get price

Helium

Apr 29, 2010How it Works Helium leak testing can be performed in several ways. Most commonly, the assembly is pressurized with helium and placed inside a vacuum chamber, explains Jacques Hoffman, president of InterTech Development Co. After air is evacuated from the chamber, a mass spectrometer tuned to helium samples the inside of the chamber. Get price

Helium Leak Detection Techniques

Helium Leak Detection Techniques VACUUM TECHNOLOGY. The sniffing method is the easiest way to detect a leak. In this method, helium is introduced into the component (or could already be present as part of the product to be tested). Helium leaking from the product to the atmosphere is detected by Get price

Helium and Hydrogen Leak Detectors, Vacuum and Sniffing

Pfeiffer Vacuum unites the leading pioneers in the field of leak detection with a broad portfolio of different leak testing technologies, which combines: Helium leak detectors. Leading air testing technologies. Leak testing CCIT solutions for Pharma. Get price

Leak rate units and calibrated leaks

Leak rate units and calibrated leaks. Leak rates can be defined in various ways and units. While the helium leak detection world is mainly using mbar l/s (or the SI-unit Pa m/s) to define leak rates, bigger leaks are often be defined in cm/min or mL/min. Get price

Leak Detection Methods

Jan 01, 2001Leak Rate (mbar l/s or atm cc/s) Helium leak test outside-in Vacuum chamber helium leak test (inside-out) Hydrogen detector Helium sniffer (inside-out) Halogen sniffer Thermoconductivity Vacuum decay Pressure decay (with pressure differential) Pressure decay (without pressure differential) Acustical Water immersion (bubble test) Bubble test (He Get price

Helium

Apr 29, 2010How it Works Helium leak testing can be performed in several ways. Most commonly, the assembly is pressurized with helium and placed inside a vacuum chamber, explains Jacques Hoffman, president of InterTech Development Co. After air is evacuated from the chamber, a mass spectrometer tuned to helium samples the inside of the chamber. Get price

Manufacturer of leak control machine, industrial leak

A gas leak testing system using Helium gas, H2 gas, includes, among other things:. A tracer gas: both helium and hydrogen are used.Pure Helium can be used for more sensitivity or can be diluted for economic reasons. Hydrogen can only be used as a tracer in a diluted form, typically in nitrogen, up to 5% (5% H2 95% N2).Hydrogen will be limited to sniffing testing in the atmosphere (see Get price

Mass spectrometer

Helium leaks in/out of the tested product in to the detector where its partial pressure is measured and displayed on a screen. The principle of leak detector is based on a sector field mass spectrometer. Analyzed entry gasses (in this case Helium) are ionized in vacuum. Ions of helium are accelerated using added voltage and further separated in Get price

Multipurpose Vacuum Leak Detectors and Helium Leak

Agilent's range of leak detection solutions ensure the safety, security and consistent performance of research, vacuum, and industrial process systems. HLD Helium Leak Detectors are rugged, precise, and easy-to-use instruments that accurately and efficiently detect leaks in Get price

TA

PA-DOP-01748, R1 Helium Leak Testing Page 4 of 24 1.0 INTRODUCTION Purpose The purposes of this procedure are to describe the process of performing helium leak testing, to provide forms for recording test results, and to define leak test acceptance criteria. The final leak test shall demonstrate the leak tightness of the finished system. Get price

Leak Detection Methods

Jan 01, 2001Leak Rate (mbar l/s or atm cc/s) Helium leak test outside-in Vacuum chamber helium leak test (inside-out) Hydrogen detector Helium sniffer (inside-out) Halogen sniffer Thermoconductivity Vacuum decay Pressure decay (with pressure differential) Pressure decay (without pressure differential) Acustical Water immersion (bubble test) Bubble test (He Get price

Helium Leak Detectors for finding leaks in vacuum systems

Phoenix Quadro Helium Leak Detector. The Phoenix Quadro is a compact helium leak detector with roughing pump (Leybold D2.5E) inside the unit. The Phoenix Quadro is a portable unit good for leak checking vacuum systems, use at power plants for leak checking condensers and other general applications where precise leak detection is needed. Get price

Phoenix L300i

The Phoenix L300i Series is a totally self-contained automatic portable helium leak detector. Unit consists of the revolutionary turbo pump specifically designed for helium leak test purposes and a 1.5 cfm two-stage direct drive, standard mechanical roughing/backing vacuum pump. Ideally suited for field service and quality control testing with Get price

Online customer service